Loading...
Ordinance 1973-014 Adopts Plumbing Code 1973 EditionORDINANCE N0. 14-73 AN ORDINANCE OF THE VILLAGE OF NORTH PALM BEACH, FLORIDA, AMENDING C}}APTER 28 OF THE VILLAGE OF NORTH PALM BEACH CODE, IT BEING T}}E PLUMBING CODE, BY ADOPTING BY REFERENCE THERETO THE 1973 EDITION OF THE SOUTHERN STANDARD PLUMBING CODE, INCLUDING APPENDIX A THERETO, AS THE PLUMBING CODE OF THE VILLAGE, AND BY MAKING CERTAIN AMENDMENTS, CORRECTIONS AND ADDITIONS TO SAID CODE. BE IT ORDINED BY THE VILLAGE COUNCIL OF NORTH PALM BEACH, FLORIDA: Section 1. Section 28-11 of the Village of North Palm Beach Code is hereby amended to read as follows: "Sec. 28-11. ADOPTED BY REFERENCE---Under the authority of Section 165.191, Florida Statutes, the Village of North Palm Beach hereby adopts by reference thereto the Southern Standard Plumbing Code, 1973 Edition, including Appendix A thereto, as the plumbing code for the Village. There has been for at least ten days last past and shall be during the time that this code is in effect, three copies of such code kept ' available for public use, inspection and examination. Section 2. Section 28-12 of the Village of North Palm Beach Code is hereby amended by adding thereto the following amendments, corrections and additions to said section: "Section 104.1 - change to read as follows: No person, firm or corporation shall connect any plumbing work with any sewers, sanitary or storm, septic tanks or sewage disposal of any kind, or private connection or install fixtures or appliances in new or existing sytems, structures or premises, or repair, or add to any existing plumbing without first applying for and obtaining a separate plumbing permit therefor from the Plumbing Official. "Section 107.2 - change to read as follows: 107.2 - Notification (a) Advance Notice: It shall be the duty of the permit holder to give reasonable advance notice to the Plumbing Official when plumbing work is ready for test or inspection. (b) Permit Holder Responsibility: It shall be the duty of the permit holder to make sure that the work will stand the test prescribed before giving the above notice. (c) Retesting: If the Plumbing Official finds that the work will not pass the test, the permit ' holder shall be required to make necessary corrections and the work shall then be resubmitted for inspection. "Section 107.3 - change to read as follows: 107.3 - Material and Labor for Tests. The equipment, material, power and labor necessary for the inspection and test shall be furnished by the permit holder. "Section 107.5 - Methods of Testing Drainage and Vent Systems - change subsection (c) to read as follows: (c) Final Test The final test of the completed drainage and vent system shall be visual and in sufficient detail to insure that the provisions of this Code have been complied with, provided however, that for cause it may be required to subject the plumbing to either a smoke or peppermint test. Where smoke test is preferred, it shall be made by filling all ' traps with water and then introducing into the entire system a pungent, thick smoke produced by one or more smoke machines. When the smoke appears at stack openings on the roof, they shall be closed and a pressure equivalent to a 1-inch water column shall be built and maintained for 15 minutes before inspection starts. Where the peppermint test is preferred, 2 ounces of oil of peppermint shall be introduced for each line of stack. "Section 427.1 - Closet Bends - add the following to the existing section: All cast iron closet bends shall be full length bends without joints from flange to soil line. "Section 427.2 - Omit deletion. "Section 506.6 - Delete entirely. "Section 1206.1 - Change paragraph (a) to read as follows: (a) Materials for underground water supply ' system and water service pipe may be a minimum of Type L copper tube, brass or cast iron pressure water pipe. Appropriate approved fittings shall be used on the water supply system or water service piping, Materials used for lawn sprinkler systems may be any of the above, or galvanized steel pipe, plastic pipe, or any combination thereof. (b) Delete "water service" in line one (1) - 2 - "Section 1212.1 - Materials - Change paragraphs (a) and (b) to read as follows: (a) Above Ground - Materials for water distribution pipes and tubing shall be brass, copper water tube, minimum Type M, stainless steel water tube, minimum Grade H lead or cast iron pressure water pipe, all to be installed with the appropriate approved fittings. ' (b) Under Ground - Inaccessible water distribution piping under floor slabs shall be minimum Type L copper tubing, brass, lead, or cast iron pressure water pipe, all to be installed with the appropriate approved fittings. "Section 1301.3 - Above Ground Piping within Buildings and Piping in Race Ways or Tunnels - Change paragraph (a) to read as follows: (a) Soil and waste piping for drainage systems shall be cast iron, lead, brass or copper tube, plastic piping, or borosilicate glass. "Section 1301.4 - Under Ground Piping within Buildings - Change paragraph (b) to read as follows: (b) For buildings over six (6) stories in height the underground pipe shall be extra heavy cast iron soil pipe, lead or Type K copper. "Section 1401.3 - Piping Above Ground - Change section to read as follows: Vent piping shall be cast iron, lead, brass, copper pipe, copper tube of a weight not less than that of copper drainage tube Type DWV, plastic piping or borosilicate glass." Section 3. This Ordinance shall take effect upon passage. PLACED ON FIRST READING THIS 27 DAY OF SEPTEMBER, 1973. PLACED ON SECOND, FINAL READING :'AND PASSED THIS 25 DAY OF OCTOBER, 1973. /s/ H. Mallory Privett, Jr, MAYOR ' ATTEST: /s/ Dolores R. Walker Village Clerk - 3 -