R2022-24 Locally Funded Agreement with FDOTRESOLUTION 2022-24
A RESOLUTION OF THE VILLAGE COUNCIL OF THE VILLAGE OF NORTH PALM
BEACH, FLORIDA, APPROVING A LOCALLY FUNDED AGREEMENT WITH THE
STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION TO PROVIDE FOR
THE FUNDING AND MAINTENANCE OF CERTAIN IMPROVEMENTS RELATED
TO THE REPLACEMENT OF THE U.S. HIGHWAY ONE BRIDGE OVER THE
EARMAN RIVER AND AUTHORIZING THE MAYOR AND VILLAGE CLERK TO
EXECUTE THE AGREEMENT; AND PROVIDING FOR AN EFFECTIVE DATE.
WHEREAS, the Florida Department of Transportation is replacing the U.S. Highway One bridge over the
Earman River (C-17 Canal) ("Project"); and
WHEREAS, the Village has requested that the Project include additional aesthetic features, including, but
not limited to, landscape planters, trash receptacles, benches, stamped concrete pavement, decorative
lighting, and lighted Village logos ("Additional Improvements"); and
WHEREAS, in order to facilitate the inclusion of the Additional Improvements in the Project, the Village
shall provide the Department with funding in accordance with the terms and conditions of a Locally Funded
Agreement and shall agree to maintain the Additional Improvements; and
WHEREAS, the Village Council determines that the adoption of this Resolution is in the interests of the
health, safety and welfare of the residents of the Village of North Palm Beach.
NOW, THEREFORE, BE IT RESOLVED BY THE VILLAGE COUNCIL OF THE VILLAGE OF
NORTH PALM BEACH, FLORIDA, as follows:
Section 1. The foregoing "whereas" clauses are hereby adopted and incorporated herein.
Section 2. The Village Council hereby approves a Locally Funded Agreement with the Florida
Department of Transportation, a copy of which is attached hereto and incorporated herein, and authorizes
the Mayor and Village Clerk to execute the Agreement. The Village Council authorizes funding in the
amount of $128,475.00, payable from Account No. I7321-66210 (Public Works/Streets & Ground —
Construction & Major Renovation), and further authorizes the Mayor and Village Manager to execute all
additional agreements required by the Locally Funding Agreement, including, but not limited to, a Three
Party Escrow Agreement, a Lighting Maintenance Memorandum of Agreement, and an Amendment to the
existing Landscape Maintenance Memorandum of Agreement.
Section 3. This Resolution shall be effective immediately upon adoption.
PASSE DOPTED THIS 24TH DAY OF MARCH, 2022.
�c R7,
ryA-�
( e Seal)
FLORIDA ;00 MAVOA
AT
VILLAGE CLERK
DocuSign Envelope ID: 8AF315A4-835A-4BBA-9D27-EA81831 FC97E
FM No: 442891-1-52-02
FEID No: VF -596-017-984
STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION
LOCALLY FUNDED AGREEMENT
THIS Locally Funded Agreement ("Agreement'), entered into this 18th day of April
2022 , by and between the State of Florida Department of Transportation hereinafter called the
DEPARTMENT, and the. Village of North Palm Beach at 501 US Highway 1, North Palm Beach, FL
33408, hereinafter called the VILLAGE.
WITNESSETH
WHEREAS, the VILLAGE is providing the DEPARTMENT with financial assistance for certain
improvements in connection with the DEPARTMENT's Bridge replacement work at SR-5/US-1
Federal Highway over the Earman River (C-'17) _ Bridge 930003 in Palm Beach County, Florida.
(Financial Management (FM) Number 442891-1-52-01, Funded in Fiscal Year 2022/2023); and
WHEREAS, the VILLAGE has requested that the DEPARTMENT perform the following additional
work: construction (install) aesthetic features (landscape planters, trash receptacles, and anchored
benches), Install stamped concrete pavement, construction (install) decorative lighting, and
construction (install) LED internally illuminated cabinet wall system (Financial Management (FM)
Number 442891-1-52-02, Funded in Fiscal Year 2022/2023) as set forth in Exhibit A attached hereto
and made a part hereof and hereinafter, referred to as the Project; and
WHEREAS, the improvements are in the interest of both the VILLAGE and the DEPARTMENT and it
would be more practical, expeditious, and economical for the DEPARTMENT to perform such
activities; and
WHEREAS, the VILLAGE bv Resolution No. 202 —�N dated the 2-t,.day of a
0--
20 Z 111)
a copy of which is attached hereto and made a part hereof, authorizes
the Mayor of the VILLAGE or designee to enter into this Agreement.
NOW, THEREFORE, in consideration of the mutual benefits to be derived from joint participation on
the Project, the parties agree to the following:
1. The recitals set forth above are true and correct and are deemed incorporated herein.
2. The DEPARTMENT shall be responsible for assuring that the Project complies with all
applicable Federal, State and Local laws, rules, regulations, guidelines and standards.
3. The VILLAGE agrees to make all previous studies, maps, drawings, surveys and other
data and information pertaining to the Project available to the DEPARTMENT at no cost.
4. The DEPARTMENT shall have the sole responsibility for resolving claims and requests
for additional work for the Project. The DEPARTMENT will make reasonable efforts to
obtain the VILLAGE 7s input in its decisions.
Page 1
5. The total cost for the Department's Bridge work and the Project is estimated to be NINE
MILLION ONE HUNDRED SIXTY THOUSAND FIVE HUNDRED FORTY EIGHT
DOLLARS AND NO CENTS ($9,160,548.00). The VILLAGE's share of the Project is an
estimated amount of ONE HUNDRED TWENTY EIGHT THOUSAND FOUR HUNDRED
SEVENTY FIVE DOLLARS AND NO CENTS ($128,475.00), which sum shall be paid to
the DEPARTMENT. In the event the actual cost of the Project is less than the funds
provided, the difference will be refunded to the VILLAGE. In the event the actual cost of
the Project, without modifications, results in a sum greater than that paid by the
VILLAGE, then such sum shall be the sole responsibility of the VILLAGE and shall be
paid to the DEPARTMENT.
(A) The VILLAGE agrees that it will, within thirty days of the execution of this Agreement,
furnish the DEPARTMENT with a check in the amount of ONE HUNDRED TWENTY
EIGHT THOUSAND FOUR HUNDRED SEVENTY FIVE DOLLARS AND NO
CENTS ($128,475.00), towards the Project costs.
In the event payment is not received by the DEPARTMENT within thirty (30) days
of execution of this Agreement the DEPARTMENT reserves the right to terminate
this Agreement and remove the Project from the DEPARTMENT's Work Program.
Remittance shall be made payable to the Department of Transportation. Payment
shall be clearly marked to indicate that it is to be applied to FM Number 442891-1-
52-02. The DEPARTMENT shall utilize this amount towards costs of Project No.
442891-1-52-02.
Payment shall be mailed to:
Florida Department of Transportation
Office of Comptroller
General Accounting Office, LFA Section
605 Suwannee Street, MS 42B
Tallahassee, Florida 32399
In lieu of mailing payment to the DEPARTMENT, the VILLAGE may also submit the
payment for the Project via wire transfer.
Wire transfer/Payments are to be made to:
Wells Fargo Bank, N.A.
Account # 4834783896
ABA # 121000248
Chief Financial Officer of Florida
Re: DOT — K 11-78, Financial project # 442891-1-52-02.
Page 2
In order for FDOT to receive credit for the funds due to the Department, the
reference line must contain "FDOT" and an abbreviated purpose, financial project
number or LFA account number.
Once the wire transfer is complete, the VILLAGE shall contact Kenneth Ward at
850-414-4886. In addition to calling Mr. Ward, the VILLAGE shall send an email
notification to Leos Kennedy at legs. ken nedyCa)-dot.state. fl. us stating the day and
time the wire transfer was sent.
(B) If the Project costs are in excess of the advance deposit amount, the VILLAGE will
provide an additional deposit within fourteen (14) calendar days of notification from
the DEPARTMENT. The DEPARTMENT will notify the VILLAGE as soon as it
becomes apparent that Project costs are in excess of the advanced deposit amount;
however, failure of the DEPARTMENT to so notify the VILLAGE shall not relieve the
VILLAGE from its obligation to pay for its full participation. If the VILLAGE cannot
provide the additional deposit within fourteen (14) calendar days, a letter must be
submitted to and approved by the DEPARTMENT's Project Manager indicating the
date the deposit will be made and the DEPARTMENT's written consent to the
payment of the additional deposit on said date. The VILLAGE understands the
request and approval of the additional time could delay the Project, and additional
costs at the VILLAGE's expense may be incurred due to delay of the Project. In the
event of non-payment, the DEPARTMENT reserves the right to terminate this
Agreement and remove the Project from the Department's Work Program.
(C) If the VILLAGE's payment for the accepted bid amount plus allowances is less than
the advance deposit amount, the DEPARTMENT will refund the amount that the
advance deposit exceeds the VILLAGE's payment for the accepted bid amount plus
allowances if such refund is requested by the VILLAGE in writing.
(D) Should Project modifications occur that increase the VILLAGE's payment for the
Project costs, the VILLAGE will be notified by the DEPARTMENT. The VILLAGE
agrees to provide, without delay, in advance of the additional work being performed,
adequate funds to ensure that cash on deposit with the DEPARTMENT is sufficient
to fully fund the cost of the Project. The DEPARTMENT shall notify the VILLAGE as
soon as it becomes apparent the actual costs will exceed the deposit amount.
However, failure of the DEPARTMENT to so notify the VILLAGE shall not relieve
the VILLAGE from its obligation to pay for its full participation. Funds due from the
VILLAGE during the Project not paid within forty (40) calendar days from the date
of the invoice are subject to an interest charge at a rate established pursuant to
Section 55.03, F.S. In the event the VILLAGE fails to make the additional payment
within the time hereinabove set forth, in addition to any other remedy, the
DEPARTMENT reserves the right to terminate this Agreement.
Page 3
(E) The DEPARTMENT intends to have its final and complete accounting of all costs
incurred in connection with the work performed hereunder within three hundred sixty
(360) days of final payment to the contractor. The DEPARTMENT considers the
Project complete when the final payment has been made to the contractor, not when
the construction work is complete. All Project cost records and accounts shall be
subject to audit by a representative of the VILLAGE for a period of three (3) years
after final close out of the Project. The VILLAGE will be notified of the final cost.
Both parties agree that in the event the final accounting of total Project costs
pursuant to the terms of this Agreement is less than the total deposits to date, the
excess funding will be refunded to the VILLAGE. If the final accounting is not
performed within three hundred sixty (360) days, the VILLAGE is not relieved from
its obligation to pay.
(F) In the event the final accounting of total Project costs indicate that the Project costs
are greater than the total deposits to date, the VILLAGE will pay the additional
amount within forty (40) calendar days from the date of the invoice from the
DEPARTMENT. The VILLAGE agrees to pay interest at a rate as established
pursuant to Section 55.03, F.S., on any invoice not paid within forty (40) calendar
days until the invoice is paid.
(G) Upon receipt of payment, from the VILLAGE to the DEPARTMENT, the
DEPARTMENT will then forward the VILLAGE's payment to the Department of
Financial Services, Division of Treasury for deposit as provided in the Three Party
Escrow Agreement (3PEA) between the VILLAGE, the DEPARTMENT and the
State of Florida, Department of Financial Services, Division of Treasury, a copy of
which is attached hereto and made a part hereof as Exhibit B.
6. The VILLAGE and the DEPARTMENT agree to maintain certain roadway and lighting
improvements. The VILLAGE and the DEPARTMENT will enter into a Lighting Maintenance
Memorandum of Agreement (LMMOA) whereby the VILLAGE shall agree to maintain the
Project in accordance with terms of the Agreement. A copy of the Agreement is attached
hereto and made part hereof as Exhibit C. The terms of this paragraph shall survive the
termination of this Agreement.
7. On December 27, 2001, the VILLAGE and the DEPARTMENT entered into a Landscape
Memorandum of Agreement (LMOA) whereby the VILLAGE agreed to maintain certain
landscape improvements. The VILLAGE and the DEPARTMENT will enter into an
Amendment to the LMOA whereby the VILLAGE shall agree to maintain the Project in
accordance with terms of the Amendment and the MMOA. A copy of the amendment is
attached hereto and made part hereof as Exhibit D. The terms of this paragraph shall
survive the termination of this Agreement.
Page 4
8. In the event it becomes necessary for either party to institute suit for the enforcement of
the provisions of this Agreement, each party shall be responsible to pay their own
attorney fees and court costs. Venue with respect to any such litigation shall be in
Broward County.
9. This Agreement and any interest herein shall not be assigned, transferred or otherwise
encumbered by the VILLAGE under any circumstances without the prior written consent
of the DEPARTMENT. However, this Agreement shall run to the DEPARTMENT and its
successors.
10. Except as otherwise set forth herein, this Agreement shall continue in effect and be
binding to both the VILLAGE and the DEPARTMENT until the Project (FM# 442891-1-
52-02) is completed as evidenced by the written acceptance of the DEPARTMENT.
11. The VILLAGE warrants that it has not employed or obtained any company or person,
other than bona fide employees of the VILLAGE, to solicit or secure this Agreement, and
it has not paid or agreed to pay any company, corporation, individual or firm, other than
a bona fide employee employed by the VILLAGE. For breach or violation of this
provision, the DEPARTMENT shall have the right to terminate the Agreement without
liability.
12. The VILLAGE / Vendor/ Contractor:
(A) shall utilize the U.S. Department of Homeland Security's E -verify system to verify
the employment eligibility of all new employees hired by the VILLAGE / Vendor/
Contractor during the term of the contract; and
(B) shall expressly require any subcontractors performing work or providing services
pursuant to the state contract to likewise utilize the U.S. Department of Homeland
Security's E -Verify system to verify the employment eligibility of all new
employees hired by the subcontractor during the contract term.
13. This Agreement is governed by and construed in accordance with the laws of the State
of Florida.
14. This document incorporates and includes all prior negotiations, correspondence,
conversations, agreements, or understandings applicable to the matters contained herein,
and the parties agree that there are no commitments, agreements or understandings
concerning the subject matter of this agreement that are not contained in this document.
Accordingly, it is agreed that no deviation from the terms hereof shall be predicated upon
any prior representation or agreements whether oral or written. It is further agreed that no
modification, amendment, or alteration in the terms and conditions contained herein shall be
effective unless contained in a written document executed with the same formality and of
equal dignity herewith.
Page 5
15. Any or all notices (except invoices) given or required under this Agreement shall be in writing
and either personally delivered with receipt acknowledged or sent by certified mail, return
receipt requested. All notices delivered shall be sent to the following addresses:
If to the DEPARTMENT:
Florida Department of Transportation - District Four
3400 West Commercial Blvd.
Fort Lauderdale, Florida 33309-3421
Attn: Leos A. Kennedy, Jr.
With a copy to: Bing Wang, P.E.
A second copy to: Office of the General Counsel
If to the VILLAGE:
Village of North Palm Beach
501 Highway US One
North Palm Beach, FL 33408
Attn: Village Manager
With a copy to: Village Attorney
The remainder of this page left intentionally blank
Page 6
DocuSign Envelope ID: 8AF315A4-835A-4BBA-9D27-EA81831 FC97E
IN WITNESS WHEREOF, this Agreement is to be executed by the parties below for the purposes
specified herein. Authorization has been given to enter into and execute this Agreement by Village of North
Palm Beach Resolution Number_ 2 -'Z , hereto attached.
VILLAGE OF NORTH PALM BEACH
BY:
NAME: -
TITLE: Chairperson/ Mayo
ATTEST:
FLORIDA :m
APPROVED:
BY: --{
ATTORNEY
STATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
DocuSigned by:
BY: Sf w 1raWA,
RRFRMMEJ PEARS
STEVEN C. BRAUN, P.E.
DIRECTOR OF TRANSPORTATION DEVELOPMENT
APPROVED: (AS TO FORM)
Lr
by:
E.Gi�n,t, �it,t,Gn M,
BY• BBaf] E484
OFFICE OF THE GENERAL COUNSEL
APPROVED:
DocuSigned by:
,�t,Sstc& A46BY: P5.7MP€6€4rm7...
DISTRICT PROGRAM MGMT. ADMINISTRATOR
Page 7
DocuSign Envelope ID: D58D5F5D-292A-4E4D-B6BC-CFA3A1A08B81
SECTION No.:
FPID No.:
COUNTY:
S.R. No.:
93040000
442891-1-52-01
Palm Beach
5
DISTRICT FOUR (4) AMENDMENT NUMBER ONE (1) TO
STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION
LANDSCAPE MEMORANDUM OF AGREEMENT
THIS AMENDMENT Number One (1) to the Agreement dated December 27, 2001, made
and entered into this 22 day of April 2022 by and between the State of
Florida Department of Transportation, hereinafter called the DEPARTMENT, and the
VILLAGE OF NORTH PALM BEACH, a municipal corporation of the State of Florida,
hereinafter called the AGENCY.
WITNESSETH:
WHEREAS, the parties entered into the Maintenance Memorandum of Agreement
dated December 27, 2001 for the purpose of maintaining the landscape improvements by the
AGENCY on State Road 5; and,
WHEREAS, the DEPARTMENT and the AGENCY have agreed to add additional
landscape to be installed on State Road 5 (US -1) in accordance with the above referenced
Agreement; and,
WHEREAS, the parties hereto mutually recognize the need for entering into an
Amendment designating and setting forth the responsibilities of each party, and
WHEREAS, the DEPARTMENT and the AGENCY entered into a Locally Funded
Agreement (LFA) wherein the Agency is funding certain improvements that are subject to this
agreement, and
NOW THEREFORE, for and in consideration of mutual benefits that flow each to the other,
the parties covenant and agree as follows:
Pursuant to paragraph 4, page 2-3 of the original Maintenance Memorandum of
Agreement for State Road 5 dated December 27, 2001, the DEPARTMENT may construct
additional landscape improvements or modify an improvement located as indicated in
Exhibit "A", State Road 5 (US -1) from M.P. 0.674 to M.P. 0.849, in accordance with the
plans attached as Exhibit "B".
S:\Transportation Development\Design\In-House Design\Landscape Architecture\AGREEMENTS\1 MOA\NORTH PALM
BEACH\SR 5_442891-1 -Earman Bridge (with LFA)\NPalmBeach_44289115201_Amend#1 - 3.17.22.docx
Page 1 of 29
2. The DEPARTMENT shall install or caused to be installed landscape improvements
described as: plant materials, irrigation and/or hardscape on the highway facilities
substantially as specified in plans and specifications hereinafter referred to as the
Project(s) and incorporated herein as referenced in Exhibit "B". Hardscape shall mean,
but not be limited to, site furnishings, landscape accent lighting, bike racks, fountains, tree
grates, decorative free standing or retaining wall(s) and/or any non-standard roadway,
sidewalk, median or crosswalk surfacing, such as, but not limited to the following: specialty
surfacing (concrete pavers, color stamped concrete and color stamped asphalt [also
known as patterned pavement]).
If there are any major changes to the plan(s), the DEPARTMENT shall provide the
modified plan(s) to the AGENCY and the AGENCY shall provide their approval or
disapproval to the DEPARTMENT within 10 business days. The DEPARTMENT may elect
to withdraw the landscape improvements if changes are not approved within the given
time frame.
3. The agency shall obtain written approval of the Department's District Landscape Architect
for the species of plants to be installed in the planters.
4. The AGENCY shall agree to maintain the additional landscape improvements as
described in paragraph 2 of the original Agreement and according to Exhibit "C"
Maintenance Plan.
5. Amending paragraph 2, page 1 of the original Maintenance Memorandum of Agreement
for State Road 5 dated December 27, 2001; the AGENCY shall maintain concrete
sidewalk in the area of the site furnishings from M.P. 0.717 to M.P. 0.755.
Except as modified by this Amendment, all terms and conditions of the original Agreement
and all Amendments thereto shall remain in full force and effect.
LIST OF EXHIBITS
Exhibit A - Landscape Improvements Maintenance Boundaries
Exhibit B - Landscape Improvement Plans
Exhibit C - Landscape Maintenance Plan
Exhibit D - Approximate Cost for Hardscape Improvements
Exhibit E - Patterned Pavement Maintenance
SATransportation Development\Design\In-House Design\Landscape Architecture\AGREEMENTS\1 MOA\NORTH PALM
BEACH\SR 5_442891-1 -Earman Bridge (with LFA)\NPalmBeach_44289115201 Amend#1 - 3.17.22.docx
DocuSign Envelope ID: D58D5F5D-292A-4E4D-B6BC-CFA3A1A08B81
IN WITNESS WHEREOF, the parties hereto have executed this Agreement effective the day
and year first above written.
AGENCY
By. •�i
Ct v LCL �'
Chairperson / Mayo Manager
� �pR7yp
Attest EAL
Clerk FLORIDA
1�
Legal Review Date
STATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
DocuSfgned by:
Sf�\tic,�. brAW ,
By: 0.RFF7QARF1FFdFF
Transportation Development Director
DocuSfgned by:
,
Attest.EE14549BD6e a.19A� 81D471... (SEAL)
Executive Secretary
Legal Review Date
Docus"ned by:
9a.ww 4/22/2022 1 3:56 PM EDT
rnn.��olnnnumop:
Office of the General Counsel
SATransportation Development\Design\In-House Design\Landscape Architecture\AGREEMENTS\1 MOA\NORTH PALM
BEACH\SR 5442891-1 -Earman Bridge (with LFA)\NPaimBeach 44289115201 Amend#1 - 3.17.22.docx
Page 3 of 29
Florida Department of Transportation
RON DESANTIS
GOVERNOR 3400 West Commercial Boulevard
Fort Lauderdale, FL 33309
JARED W. PERDUE, P.E.
SECRETARY
Improve Safety, Enhance Mobility, Inspire Innovation
www.fdot.gov
April 27, 2022
Mr. Andy Lukasik
Village Manager
Village of North Palm Beach
501 US Highway 1
North Palm Beach, Florida 33408
RE: Locally Funded Agreement (LFA)
FM: 442891-1-52-02
Description: Construction (install) aesthetic features (landscape planters, trash receptacles,
and anchored benches), Install stamped concrete pavement, construction (install)
decorative lighting, and construction (install) LED internally illuminated cabinet
wall system during the Department’s bridge replacement work at SR-5/US-1
Federal Highway over the Earman River (C-17) Bridge 930003
Dear Mr. Lukasik:
Enclosed please find a copy of a fully executed Three Party Escrow Agreement for the above
referenced project. Said documents are to be retained for your records.
If you have any questions, please do not hesitate to contact me. I can be reached at (954) 777-
2285.
Sincerely,
Leos A. Kennedy, Jr.
Program Management Unit
District Four
enc: LFA
copy: Bing Wang, P.E., Project Manager
Mark Madgar, Work Program Manager
LFA Section
File
DocuSign Envelope ID: DC1 C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.:
93040000 / 02
FM No.(s):
442891-1-52-01
COUNTY:
Palm Beach
S.R. No.:
SR 5/US 1
DISTRII.'#'T FOUR
LIGHTING MAINTENANCE MEMORANDUM OF AGREEMENT
THIS AGREEMENT made and entered into this date 04/29/2022 , by
and between the STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION, a component
AGENCY of the State of Florida, hereinafter called the DEPARTMENT, and Village of North
Palm Beach, a municipal corporation existing under the Laws of Florida, hereinafter called the
AGENCY.
WITNESSETH:
WHEREAS, the DEPARTMENT has jurisdiction over State Road 5/ US1 beginning
from State Road (SR) 5 / Mile Post (M.P.) M.P. 0.622 to 0.849 and
WHEREAS, the DEPARTMENT seeks to install and have maintained by the AGENCY
certain highway IMPROVEMENTS; and
WHEREAS, as part of the continual updating of the State of Florida Highway System, the
DEPARTMENT, for the purpose of safety, protection of the investment and other reasons, has
constructed and does maintain SR 5 beginning from M.P. 0.622 to M.P. 0.849 (within the limits
of the AGENCY); and
WHEREAS, it is the intent of the AGENCY and the DEPARTMENT that the AGENCY shall
maintain the specific elements constructed under Project Number 442891-1-52-01 to include
decorative coated light poles, illuminated "The Village of North Palm Beach" logo signs and
Florida Power & Light (FPL) new roadway lighting; hereinafter called IMPROVEMENTS installed
along SR 5 M.P. 0.622 to M.P. 0.849; and
WHEREAS, the Project involves the scope of work as described within Exhibit A
(Project Location, Description and Aerial) and Exhibit B (Construction Plans), which will
benefit the AGENCY; and
WHEREAS the parties hereto mutually recognize the need for entering into an
AGREEMENT designation and setting forth the responsibilities of each party; and
WHEREAS the AGENCY by Resolution Number 2022-24 entered this date
03/24/2022 , attached hereto and by this reference made a part hereof, desires to enter
into this AGREEMENT and authorizes its officers to do so;
NOW THEREFORE, for and in consideration of the mutual benefits to flow each to the
other, the parties covenant and agree as follows:
1. RECITALS
The recitals set forth above are true and correct and are deemed incorporated herein.
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
2. INSTALLATION OF FACILITIES
A. The DEPARTMENT has issued Project Number 442891-1-52-01 to construct the
IMPROVEMENTS as detailed in Exhibit A and Exhibit B that will benefit the AGENCY.
B. The IMPROVEMENTS shall comply with the laws and regulations relating to the
Americans with Disabilities Act of 1990, as currently enacted or as may be amended from
time to time ("ADA"). If there are any major changes to the plan(s), the DEPARTMENT
shall provide the modified plan(s) to the AGENCY and the AGENCY shall provide their
approval or disapproval to the DEPARTMENT within ten (10) business days. The
DEPARTMENT may elect to withdraw the IMPROVEMENTS if changes are not approved
within the given time frame.
C. The AGENCY shall be invited to assist the DEPARTMENT in final inspection before
acceptance of the job by the DEPARTMENT.
D. The AGENCY must maintain the IMPROVEMENTS associated within the limits of the
project.
3. MAINTENANCE OF FACILITIES
A. The AGENCY agrees to maintain the IMPROVEMENTS to be installed under Project
Number 442891-1-52-01 within the limits of construction. Maintenance by the AGENCY
will include but not limited to inspection, repair, restoration, replacement, coating
replacement and general maintenance of all decorative or non-standard features within
the limits of construction. IMPROVEMENTS are defined as items requested by the
AGENCY that are not defined in the DEPARTMENT'S Design Standards. This includes
Project Number 442891-1-52-01 for decorative coated light poles, illuminated “The
Village of North Palm Beach” logo signs and FPL new roadway lighting installed along SR
5, from M.P. 0.622 to M.P. 0.849.
1) The AGENCY agrees to maintain, at its sole cost and expense, the
IMPROVEMENTS set forth in Exhibit A in compliance with any and all applicable laws
which shall include, but not be limited to, laws and regulations relating to the Americans
with Disabilities Act ("ADA") of 1990, as currently enacted or as may be amended from
time to time.
2) The IMPROVEMENTS shall be kept clean and free from trash and debris.
Maintenance and cleaning of all IMPROVEMENTS shall comply with the Department’s
Stormwater Pollution Prevention Plan and National Pollutant Discharge Elimination
System (NPDES) Stormwater Pollution Prevention Plan and all other environmental laws.
The IMPROVEMENTS shall be kept free of graffiti. The IMPROVEMENTS shall be free
of pests such as stinging insects, rodents, and vermin, including removal of nests as
needed.
3) As part of the maintenance responsibility, the AGENCY shall keep in good repair
and replace, defective or worn-out parts of the IMPROVEMENTS. The AGENCY's
2
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
responsibility to keep the IMPROVEMENTS in good repair shall include all necessary
inspection, maintenance, repair and replacement of any type or nature, including, but not
limited to, maintenance, repair, coating replacement, and replacement due to normal
wear and tear, named storm event, acts of God, vandalism, and accidents. The AGENCY
shall take all necessary steps to maintain the IMPROVEMENTS in a manner to protect
against injury to any person or property.
4) The AGENCY shall perform all activities necessary to keep the IMPROVEMENTS
fully operating, properly functioning, with a minimum of 90% of the lights burning for any
lighting type or roadway system at all times in accordance with the original design thereof,
whether necessitated by normal wear and tear, accidental or intentional damage, or acts
of nature. Said maintenance shall include, but shall not be limited to, providing electrical
power, and paying all charges associated therewith, routine inspection and testing,
preventative maintenance, emergency maintenance, replacement of any component
parts of the IMPROVEMENTS (including the poles and all other component parts
installed as part of the IMPROVEMENTS), and locating (both vertically and horizontally)
the IMPROVEMENTS, as may be necessary.
5) The above-named functions to be performed by the AGENCY may be subject to
periodic inspections by the DEPARTMENT at the discretion of the DEPARTMENT. Such
inspection findings will be shared with the AGENCY and shall be the basis of all decisions
regarding, reworking relating to the maintenance obligation I function or AGREEMENT
termination.
6) The AGENCY shall be solely responsible for any damages to surrounding
property, real estate, vehicles, pedestrians, or other assets occurring as a result of
maintenance and operation of the IMPROVEMENTS and shall repair such damage to
the satisfaction of the DEPARTMENT at no expense to the DEPARTMENT, as per the
requirements in Exhibit C (Maintenance Plan Requirements).
7) The AGENCY shall be responsible to maintain the light pole structures and
electrical components. The AGENCY shall replace the structure if destroyed in an
accident by third parties. The DEPARTMENT expressly assigns its rights, interests and
privileges pertaining to said IMPROVEMENTS’ damage to the AGENCY, so AGENCY
can pursue all claims and causes of actions against the third parties responsible for the
damage. The DEPARTMENT will assist the AGENCY as necessary and will confirm
AGENCY’S authorization to pursue recovery. The AGENCY will be responsible for all
attorneys’ fees and costs incurred in its recovery activities. The AGENCY shall not file
suit in the name of the DEPARTMENT.
B. The AGENCY shall indemnify the DEPARTMENT for any and all costs or expenses
incurred by the DEPARTMENT for the AGENCY'S failure to comply with all ADA Laws
existing and as may be amended. Costs and expenses shall include the costs to make
the facility ADA compliant, Attorney's fees and costs and any judgments. Adjacent
sidewalk areas shall be accessible at all times. If sidewalk closures are needed, alternate
routes shall be clearly identified, and missing sidewalk shall be restored either with
permanent or temporary materials at the end of each workday.
3
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
C. All IMPROVEMENTS shall at all times have a notification sign posted with the name and
phone number of the DEPARTMENT within the AGENCY responsible for maintenance of
the IMPROVEMENTS so that members of the public may contact AGENCY regarding
problems with the IMPROVEMENTS. The AGENCY shall promptly respond and correct
all complaints regarding maintenance. The IMPROVEMENTS to be constructed with this
project shall not contain advertising. Nor shall advertising be placed upon them by any
party in the future.
D. It is understood and agreed by the parties that upon "final acceptance" (as that term is
described in the Standard Specifications for Roadway and Bridge Construction, as
amended by contract documents section 5-11) by the DEPARTMENT of the Project and
Notice thereof to the AGENCY, the AGENCY shall be responsible for maintenance of the
Project in accordance with the following Federally and State accepted standards (current
editions at the time of execution of this AGREEMENT and any amendments hereafter)
and all costs related thereto: (a) FDOT Design Manual (FDM), (b) Florida Green Book, (c)
Standard Specifications for Roadway and Bridge Construction, (d) FDOT Standard Plans
for Roadway Construction, (e) Manual on Uniform Traffic Control Devices (MUTCD), and
(f) all other applicable local, state, or federal laws, rules, resolutions, or ordinances, and
FDOT procedures. In the event of a conflict between documents, standards, and
procedures the more stringent shall apply.
E. Any work impacting traffic flow along SR 5 must be coordinated with the DEPARTMENT.
Lane closures must be submitted for approval in accordance with DEPARTMENT
procedures and policies and will meet the goals established in the DEPARTMENT's
Open Roads Policy.
4. NOTICE OF MAINTENANCE DEFICIENCIES
A. If, at any time while the terms of this AGREEMENT are in effect, it shall come to the
attention of the DEPARTMENT that the AGENCY's responsibility as established herein
or a part thereof is not being properly accomplished pursuant to the terms of this
AGREEMENT, the DEPARTMENT may issue a written notice, that a deficiency or
deficiencies exist(s), by sending a certified letter to the AGENCY, in care of the VILLAGE
OF NORTH PALM BEACH CITY MAYOR, to place the AGENCY on notice regarding its
maintenance deficiencies. Thereafter, the AGENCY shall have a period of sixty (60) days
within which to correct the citied deficiency or deficiencies. It said deficiencies are not
corrected within the time period, the DEPARTMENT may, at its option, proceed under
one or more or a combination of the following items:
1) The DEPARTMENT may repair any item or a number of items. Corrective actions
will be performed with the DEPARTMENT and/or its independent contractor's
materials, equipment, and personnel. The actual cost for such work will be charged
to the AGENCY.
2) The DEPARTMENT may remove or replace any item or number of items with the
standard DEPARTMENT item. Corrective actions will be performed with the
4
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
DEPARTMENT and/or its independent contractor's materials, equipment, and
personnel. The actual cost for such work will be charged to the AGENCY.
3) If there is no standard equivalent item or if in the DEPARTMENT's discretion the item
is not necessary for the operations of the roadway, the DEPARTMENT may remove
the item in its entirety and restore the area to a condition acceptable to the
DEPARTMENT. Corrective actions will be performed with the DEPARTMENT and/or
its independent contractor's materials, equipment, and personnel. The actual cost for
such work will be charged to the AGENCY.
4) At the discretion of the DEPARTMENT, terminate the AGREEMENT in accordance
with Paragraph 7 of this AGREEMENT and remove, by the DEPARTMENT or its
Contractor's personnel, all the IMPROVEMENTS installed under this AGREEMENT
and charge the AGENCY the reasonable cost of such removal.
5. FUTURE DEPARTMENT IMPROVEMENTS
It is understood between the parties hereto that the IMPROVEMENTS covered by this
AGREEMENT may be removed, relocated, or adjusted at any time in the future as
determined to be necessary by the DEPARTMENT in order that the adjacent state road be
widened, altered, or otherwise changed to meet with future criteria or planning of the
DEPARTMENT.
6. FUTURE AGENCY IMPROVEMENTS
The AGENCY may construct additional IMPROVEMENTS within the limits of the rights of
ways identified as a result of this document subject to the following conditions:
1) Plans for any new IMPROVEMENTS shall be subject to approval by the
DEPARTMENT. The AGENCY shall not change or deviate from said plans without
written approval by the DEPARTMENT.
2) The AGENCY shall procure a permit and/ or Construction AGREEMENT from the
DEPARTMENT, as appropriate.
3) All IMPROVEMENTS shall be developed and implemented in accordance with
appropriate state safety and roadway design standards.
4) The AGENCY agrees to comply with the requirements of this AGREEMENT
regarding any additional IMPROVEMENTS installed at no cost to the
DEPARTMENT.
7. AGREEMENT TERMINATION
This AGREEMENT may be terminated under anyone (1) of the following conditions:
1) By the DEPARTMENT, if the AGENCY fails to perform its duties under this
AGREEMENT, following ten (10) days written notice. The AGENCY shall reimburse
5
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
the DEPARTMENT for any expenditures for the installation of said IMPROVEMENTS
and the cost to remove and or replace said improvement with the standard
improvement or remove in its entirety.
2) By the DEPARTMENT, for refusal by the AGENCY to allow public access to all
documents, papers, letters, or other material subject to the provisions of Chapter 119,
Florida Statutes, and made or received by the AGENCY in conjunction with this
AGREEMENT.
3) Only if mutually agreed to by both parties with a six (6) month written notice.
8. AGREEMENT TERM
The term of this AGREEMENT commences upon execution by all parties. The term of this
AGREEMENT shall remain in effect for as long as the IMPROVEMENTS shall exist.
9. LIABILITY AND INSURANCE REQUIREMENTS
A. With respect to any of the AGENCY'S agents, consultants, sub-consultants, contractors,
and/or sub-contractors, such party in any contract for the IMPROVEMENTS shall agree
to indemnify, defend, save and hold harmless the DEPARTMENT from all claims,
demands, liabilities, and suits of any nature arising out of, because of or due to any
intentional and/or negligent act or occurrence, omission or commission of such agents,
consultants, sub consultants, contractors and/or subcontractors. The AGENCY shall
provide to the DEPARTMENT written evidence of the foregoing upon the request of the
DEPARTMENT. It is specifically understood and agreed that this indemnification clause
does not cover or indemnify the DEPARTMENT for its own negligence.
B. In the event that AGENCY contracts with a third party to provide the services set forth
herein, any contract with such third party shall include the following provisions:
1) AGENCY'S contractor shall at all times during the term of this AGREEMENT keep
and maintain in full force and effect, at contractor's sole cost and expense,
Comprehensive General Liability with minimum limits of $1,000,000.00 per
occurrence combined single limit for Bodily Injury Liability and Property Damage
Liability and Worker's Compensation insurance with minimum limits of $500,000.00
per Liability. Coverage must be afforded on a form no more restrictive that the latest
edition of the Comprehensive General Liability and Worker's Compensation policy
without restrictive endorsements, as filed by the Insurance Services Office and shall
name the DEPARTMENT as an additional insured.
2) AGENCY'S contractor shall furnish AGENCY with Certificates of Insurance of
Endorsements evidencing the insurance coverages specified herein prior to the
beginning performance of work under this AGREEMENT.
3) Coverage is not to cease and is to remain in full force and effect (subject to
cancellation notice) until all performance required of AGENCY'S contractor is
completed. All policies must be endorsed to provide the DEPARTMENT with at
6
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
least thirty (30) days' notice of cancellation and or/or restriction. If any of the
insurance coverages will expire prior to the completion of work, copies of renewal
policies shall be furnished at least (30) days prior to the date of expiration.
10. E-VERIFY REQUIREMENTS
The AGENCY shall:
1) Utilize the U.S. DEPARTMENT of Homeland Security's E-Verify system to verify the
employment eligibility of all new employees hired by the AGENCY for the work
performed under this AGREEMENT; and
2) Expressly require any contractors performing work or providing services pursuant to
the state contract to likewise utilize the U.S. DEPARTMENT of Homeland Security's
E-Verify system to verify the employment eligibility of all new employees hired by the
subcontractor during the contract term.
11. ENTIRE AGREEMENT
This writing embodies the entire Agreement and understanding between the parties
hereto and there are no other Agreements and understanding, oral or written, with
reference to the subject matter hereof that are not merged herein and superseded hereby
except the Local Funded Agreement(s) and State Highway Lighting Maintenance and
Compensation Agreement(s) signed between the parties, as amended, as to all other
IMPROVEMENTS not specifically mentioned in this Agreement. The streetlights installed
under this project will be compensated as streetlights under the State Highway Lighting
Maintenance and Compensation Agreement. If the DEPARTMENT and AGENCY fail to
agree on the annual lump sum amount to be paid under the State Highway Lighting
Maintenance and Compensation Agreement, this Agreement shall supersede that
Agreement and the AGENCY agrees to maintain the lights solely under this Agreement.
12. EXPENDITURE OF MONEY
The DEPARTMENT, during any fiscal year, shall not expend money, incur any liability, or
enter into any contract which, by its terms, involves the expenditure of money in excess of
the amounts budgeted as available for expenditure during such fiscal year. Any contract,
verbal or written, made in violation of this subsection is null and void, and no money may be
paid on such contract. The DEPARTMENT shall require a statement from the Comptroller of
the DEPARTMENT that funds are available prior to entering into any such contract or other
binding commitment of funds. Nothing herein contained shall prevent the making of contracts
for periods exceeding one (1) year, but any contract so made shall be executory only for the
value of the services to be rendered or agreed to be paid for in succeeding fiscal years; and
this paragraph shall be incorporated verbatim in all contracts of the DEPARTMENT which
are for an amount in excess of TWENTY-FIVE THOUSAND DOLLARS ($25,000.00) and
which have a term for a period of more than one year.
7
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
13. DISPUTES
The DEPARTMENT'S District Secretary shall decide all questions, difficulties, and disputes
of any nature whatsoever that may arise under or by reason of this AGREEMENT, the
prosecution or fulfillment of the service hereunder and the character, quality, amount and
value thereof; and his decision upon all claims, questions and disputes shall be final and
conclusive upon the parties hereto.
14. ASSIGNMENT
This AGREEMENT may not be assigned or transferred by the AGENCY in whole or part
without the consent of the DEPARTMENT.
15. LAWS GOVERNING
This AGREEMENT shall be governed by and construed in accordance with the laws of the
State of Florida. In the event of a conflict between any portion of the contract and Florida law,
the laws of Florida shall prevail. Venue with respect to judicial proceedings arising out of this
AGREEMENT shall be in Broward County, Florida.
16. NOTICES
All notices given or required under this AGREEMENT shall be in writing and either personally
delivered with receipt acknowledgement or sent by certified mail, return receipt requested.
All notices shall be sent to the following addresses.
If to the DEPARTMENT:
State of Florida Department of Transportation
Attention: District Maintenance Engineer
3400 West Commercial Blvd
Ft. Lauderdale, FL 33309-3421If to the
AGENCY:
Village Of North Palm Beach
Attention: City Mayor
17. LIST OF EXHIBITS
Exhibit A: Project Location, Description and Aerial
Exhibit B: Lighting Plans
Exhibit C: Maintenance Plan Requirements
8
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
IN WITNESS OF THE FOREGOING, the parties have set their hands and seals the day and
year first above written.
DEPARTMENT:
STATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
Sign: ___________________________
Director of Operations
Print Name: Paul A. Lampley
Date: ____________________________
Approval as to Form:
Sign: ___________________________
District General Counsel
Print Name: Dawn Raduano
Date: ____________________________
10
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
4/20/2022 | 3:37 PM EDT
4/29/2022 | 8:00 AM EDT
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
EXHIBIT A
PROJECT LOCATION, DESCRIPTION AND AERIAL
I. Location:
The IMPROVEMENTS associated with this AGREEMENT are located in the Village of North
Palm Beach, in Palm Beach County, Florida along State Road 5 beginning M.P. 0.622 to M.P.
0.849.
II. Description of Work:
Project Number 442891-1-52-01 to include decorative color coated painted light poles with Light-
emitting Diode (LED) fixtures, standard aluminum light poles with LED fixtures, utility conflict
poles with LED fixtures, and lighting retrofit of existing high pressure sodium lighting fixtures to
LED fixtures, illuminated “The Village of North Palm Beach” logo signs.
It will be the responsibility of the AGENCY to maintain the IMPROVEMENTS described in this
AGREEMENT.
III. Aerial
11
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
EXHIBIT B
LIGHTING PLANS
Lighting Plans prepared by Gordon D. Ziecina, P.E., dated January 13th, 2022, as approved by
the DEPARTMENT.
LIGHTING PLANS (attached)
Sheets Included:
PDF Page Number (#) Plan Sheet (#) Sheet(s) Description
13 L-1 KEY SHEET
14 L-2 TABULATION OF QUANTITIES
15 L-3 GENERAL NOTES
16 L-4 POLE DATA AND LAGEND
17 - 19 L-5 thru L-7 LIGHTING PLAN
20 - 23 L-8 thru L-11 LIGHTING DETAIL SHEET
24 - 25 L-12 thru L-13 SERVICE POINT DETAIL
[The remainder of this page intentionally left blank.]
12
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
STATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
NO.
SHEET
YEAR
FISCAL
FINANCIAL PROJECT ID 442891-1-52-01
PALM BEACH COUNTY (93040)
23
EXPRESSWAY
T
U
R
NPI
KE
10
PENSACOLA FORT WALTON
BEACH
PANAMA
CITY
CHIPLEY
TALLAHASSEE
75
10
295
95
JACKSONVILLE
ST AUGUSTINE
GAINESVILLE
OCALA DAYTONA BEACH
DELAND 4
NEW PORT RICHEY
TAMPA
75
4
LAKELAND
MELBOURNE -
COCOA
ORLANDO
BARTOWST PETERSBURG
275
SARASOTA -
BRADENTON
75
95
FT PIERCE
FT MYERS
WEST PALM
BEACH
FT LAUDERDALE
MIAMI
75
75
NAPLES
KEY WEST
CITY
LAKE
FLORIDA'S
BEACH LINE
CONTRACT NO.
CONSTRUCTION
SHEET DESCRIPTIONSHEET NO.
FDOT PROJECT MANAGER:
BING WANG, P.E.
TBD L-1
(FEDERAL FUNDS)
CONTRACT PLANS
LIGHTING PLANS
INDEX OF LIGHTING PLANS
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\KEYSLT01.DGNUSER: 5lamarj 1/13/2022 4:42:55 PM Default
SR-5/US-1 OVER EARMAN RIVER (C-17) BRIDGE 930003
LOCATION OF PROJECT
https://goo.gl/maps/mHnZ8BDmik14ji9r5
THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.*REPORT OF CORE BORINGSGL-1 thru GL-2
and sealed document.
This sheet is contained in a separate digitally signed
only to indicate that it is part of the Lighting Plans.
* These sheets are included in the Index of Lighting Plans
ENGINEER OF RECORD
LIGHTING PLAN
STATE OF
���
No 33770
REENIGNE LANO
ISS
EFORP ESNECIL
ADIROLF A
NICEIZ .D NODRO
GVENDOR NO.: 043682340.001
CONTRACT NO.: C9V86
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
P.E. NO.: 33770
Gordon D. Ziecina, P.E.
ON ANY ELECTRONIC COPIES.
AND THE SIGNATURE MUST BE VERIFIED
NOT CONSIDERED SIGNED AND SEALED
PRINTED COPIES OF THIS DOCUMENT ARE
ON THE DATE ADJACENT TO THE SEAL
SIGNED AND SEALED BY:
THIS ITEM HAS BEEN DIGITALLY
FEBRUARY, 2022.
BIDDABILITY SUBMITTAL
SERVICE POINT DETAIL L-12 thru L-13
LIGHTING DETAIL SHEET L-8 thru L-11
L-5 thru L-7 LIGHTING PLAN
L-4 POLE DATA AND LEGEND
L-3 GENERAL NOTES
L-2 TABULATION OF QUANTITIES
L-1 KEY SHEET
13
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
L-2
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\TABQLT01.dgnUSER: 5lamarj 1/13/2022 4:42:57 PM Default
442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
TABULATION OF QUANTITIES
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.ITEM NOTE.
WILL BE REMOVED AND DISPOSED OF BY THE FDOT CONTRACTOR. EXCEPT THE LUMINAIRES AS NOTED IN THE LIGHT POLE REMOVAL PAY
EXISTING LIGHTING CONDUCTORS (715-1-60). ALL INCIDENTAL ITEMS ASSOCIATED WITH THE EXISTING LIGHT POLES (I.E. PULL BOXES ETC.)
THE TWO GROUND MOUNTED LOAD CENTERS, THE NPB VILLAGE LOGO SIGNS, REMOVE THE EXISTING LIGHT POLES (715-4-70), AND THE
CONCRETE POLE AT STA. 275+41 46' RT, INSTALL ALL BRIDGE MOUNTED JUNCTION BOXES, BRIDGE MOUNTED CONDUIT WITH CONDUCTORS,
THE FDOT CONTRACTOR SHALL INSTALL THE TWO BRIDGE MOUNTED LIGHT POLES AT STA. 274+25 60' RT, 274+25 61' LT, THE DECORATIVE
FDOT CONTRACTOR:
PROPERLY.
INSTALL THE DECORATIVE LIGHT FIXTURES, COMPLETE THE ELECTRICAL WIRING, AND VERIFY THE LIGHT FIXTURES ARE FUNCTIONING
CONTRACTOR INSTALLS THE BRIDGE MOUNTED LIGHT POLES, AND THE DECORATIVE CONCRETE LIGHT POLE, THE FPL CONTRACTOR WILL
CONDUIT, BRIDGE MOUNTED JUNCTION BOXES, THE TWO GROUND MOUNTED LOAD CENTERS, AND THE REMOVAL ITEMS. AFTER FDOT
LIGHT POLES AT STA. 274+25 60' RT, 274+25 61' LT, THE DECORATIVE CONCRETE POLE AT STA. 275+41 46' RT. THE BRIDGE MOUNTED
THE FPL CONTRACTOR SHALL PERFORM ALL WORK SHOWN IN THESE PLANS EXCEPT FOR THE INSTALLATION OF THE TWO BRIDGE MOUNTED
FPL CONTRACTOR:
ALLOCATION OF WORK BETWEEN FPL CONTRACTOR AND FDOT CONTRACTOR:
FPL CONTRACTOR TABULATION OF QUANTITIES
DESCRIPTION UNIT
SHEET NUMBERS
SHEET
THIS
TOTAL
TOTAL
GRAND
L-5 L-6 L-7 L-8 L-9
PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL
CONDUIT, FURNISH & INSTALL, OPEN TRENCH LF 75 208 67 350 350
CONDUIT, FURNISH & INSTALL, DIRECTIONAL BORE LF 198 475 130 803 803
PULL & SPLICE BOX, F&I, 13" x 24"EA
LUMINAIRE & BRACKET ARM, MOUNTED ON FPL TRANSMISSION POLE EA 3 1 4 4
LUMINAIRE ONLY INSTALL ON DECORATIVE POLES INSTALLED BY FDOT CONTRACTOR EA 3 3 3
LIGHTING CONDUCTORS, F&I, NO 1/0 TPX LF 273 1024 329 1626 1626
POLE CABLE DISTRIBUTION SYSTEM, CONVENTIONAL FURNISH & INSTALL EA 2 4 1 7 7
LIGHT POLE COMPLETE- SPECIAL DESIGN, F&I, SINGLE ARM SHOULDER MOUNT, CONCRETE, 30'EA 2 4 1 7 7
FDOT CONTRACTOR TABULATION OF QUANTITIES
NO.
ITEM
PAY
DESCRIPTION UNIT
SHEET NUMBERS
SHEET
THIS
TOTAL
TOTAL
GRAND
L-5 L-6 L-7 L-8 L-9
PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL
630 2 15 CONDUIT, FURNISH & INSTALL, BRIDGE MOUNT LF 176 40 40 256 256
635 2 11 PULL AND SPLICE BOXES, F&I, 13" X 24"EA 4 1 5 5
635 3 12 JUNCTION BOX, F&I, MOUNTED EA 2 2 2 6 6
639 3 11 ELECTRICAL SERVICE DISCONNECT, F&I, POLE MOUNT EA 1 1 2 2
641 2 12 PRESTRESSED CONCRETE POLE, F&I, TYPE P-II SERVICE POLE EA 1 1 2 2
700 5 40 INTERNALLY ILLUMINATED SIGN, INSTALL ONLY, FURNISHED BY VILLAGE OF NORTH PALM BEACH EA 2 2 4 4
715 1 15 LIGHTING CONDUCTORS, F&I, NO. 1/0 TPX LF 176 176 176
715 1 60 LIGHTING CONDUCTORS, REMOVE & DISPOSE, CONTRACTOR OWNS LF 112 680 280 1072 1072
715 4 50 LIGHT POLE COMPLETE, INSTALL ONLY, DECORATIVE CONCRETE POLE 30' MOUNTING HEIGHT EA 1 1 1
715 4 70 LIGHT POLE COMPLETE, REMOVE POLE AND FOUNDATION EA 1 5 2 8 8
715 7 11 LOAD CENTER, F&I, SECONDARY VOLTAGE AS 1 1 2 2
715 500 1 POLE CABLE DISTRIBUTION SYSTEM, CONVENTIONAL EA 3 3 3
715 535 130 LIGHT POLE COMPLETE - DECORATIVE BRIDGE MOUNTED POLE, INSTALL ONLY, SINGLE ARM - ALUMINUM 30'EA 2 2 2
14
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
L-3
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\GNNTLT01.dgnUSER: 5lamarj 1/13/2022 4:42:59 PM Default
442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
GENERAL NOTES
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.WIRING, AND FIXTURE ARMS ONLY.
PAY ITEM 715-535-130: FDOT CONTRACTOR TO INSTALL BRIDGE MOUNTED POLES, ELECTRICAL
FDOT CONTRACTOR TO FURNISH AND INSTALL LIGHTING LOAD CENTER WITHIN FDOT ROADWAY AS SHOWN ON PLANS.
FPL CONTRACTOR TO FURNISH AND INSTALL POWER SERVICE POINT AS SHOWN ON PLANS.
PAY ITEM 715-7-11 1AS
NORTH PALM BEACH 33408
645 PROSEPERITY FARMS ROAD
PH NO. 561-641-3443
ASSISTANT PUBLIC WORKS DIRECTOR/VILLAGE OF NORTH PALM BEACH
MR. KEN HERN
LUMINAIRES DELIVERED TO:
SHALL BE DISPOSED OF BY THE CONTRACTOR.
CONTRACTOR IS TO DELIVER THE LUMINAIRES TO THE VILLAGE OF NORTH PALM BEACH. ALL OTHER REMOVAL ITEMS
EXISTING CONDITIONS.
WIRING, ETC). THIS PAY ITEM INCLUDES THE RESTORATION OF THE AREA OF THE REMOVED LIGHTING POLE TO MATCH
LUMINAIRES, AS WELL AS ALL INCIDENTAL ITEMS ASSOCIATED WITH THE LIGHT POLES (I.E. PULL BOXES, CONDUIT
PAY ITEM 715-4-70: PAYMENT INCLUDES REMOVAL OF DIRECT BURIAL LIGHTING POLES, FIXTURE MOUNTING ARMS,
AND IN CONDUIT TO COMPLETE LIGHTING CIRCUITS A & B FOR ALL LIGHTING FIXTURES.
FOR FDOT CONTRACTOR ONLY. FPL CONTRACTOR TO INSTALL SUFFICENT LENGTH OF #1/0 TPX CONDUCTOR OVERHEAD
PAY ITEM NUMBER 715-1-15 (LIGHTING CONDUCTORS): ARE QUANTIFIED AS POINT TO POINT PLAN DISTANCE
ALL CONDUITS SHALL BE 1 RUN - 2" UNLESS OTHERWISE NOTED ON PLANS.
PAY ITEM 630-2-15:
LIGHTING PAY ITEM FOOTNOTES:
BENDS SHALL BE NOT LESS THEN RECOMMENDED BY N.E.C. OR N.E.S.C. FOR CABLE USED.
MANUFACTURER'S REQUIREMENTS, USE PULLING COMPOUND PER MANUFACTURER'S REQUIREMENTS. ALL
PULLING INSTRUCTIONS: CONNECT PULLING DEVICES TO COPPER WIRE AND NOT TO JACKET AND MEET6.
PERFORMANCE OF WORK AROUND PRIMARY HIGH VOLTAGE COMPONENTS.
TAKING SAFETY PRECAUTIONS AS NECESSARY, EXERCISE EXTREME CAUTION AT ALL TIMES IN
THAT IS WITHIN 10' OF ENERGIZED ELECTRICAL CONDUCTORS. FPL, AT ITS OPTION, MAY ASSIST IN
NOTIFY TREVOR BUYS (561-267-5266) WITH FPL AT LEAST 48 HOURS PRIOR TO ANY INSTALLATION5.
ELECTRIC CODE, THE NATIONAL ELECTRICAL SAFETY CODE AND FDOT STANDARD SPECIFICATIONS.
ALL ELECTRICAL WORK SHALL MEET ALL REQUIREMENTS OF THE LATEST EDITIONS OF THE NATIONAL4.
FIELD CONDITIONS AND EXISTING UTILITY LOCATIONS.
AND MAY BE SHIFTED BY THE CONTRACTOR WITH THE APPROVAL OF THE ENGINEER TO ACCOMMODATE
THE LOCATION OF THE LUMINAIRES, CONDUITS, AND JUNCTION BOXES ARE DIAGRAMMATIC ONLY 3.
EXCAVATION OR DEMOLITION OPERATIONS.
CONTACT SUNSHINE ONE-CALL AS REQUIRED BY CHAPTER 556 OF THE FLORIDA STATUES PRIOR TO2.
D) CONDUCTORS
C) LOAD CENTER EQUIPMENT
B) LUMINAIRE CUT SHEETS,
A) CONNECTION HARDWARE FOR CONDUIT, ELBOW SWEEPS, ETC.
INCLUDES:
EQUIPMENT SPECIFICATION OR DESIGN DATA FOR ALL MATERIAL PROPOSED FOR THE PROJECT AND
PRIOR TO ANY EQUIPMENT ORDER, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL,1.
LIGHTING NOTES
LOAD CENTER "A"
120 V, SINGLE PHASE TO NEUTRAL, 3 WIRE
STA. 273+05 RT
DESIGNATION
LOAD CENTER AND CIRCUIT
BREAKER SIZES
MAIN & CIRCUIT
LOAD (AMPS)
TOTAL CONNECTED
(AMPS)
TOTAL DEMAND LOAD
(KVA)
DESIGN LOAD
OVERCURRENT
LOAD CENTER "A"100 AMPS 2P (MAIN)15.34 19.18 2.30
A-1 40 AMPS 2P (BRANCH)15.34 19.18
SPARE 40 AMPS 2P (SPARE)
PROP LOAD CENTER "B"
120 V, SINGLE PHASE TO NEUTRAL, 3 WIRE
STA. 280+71 LT
DESIGNATION
LOAD CENTER AND CIRCUIT
BREAKER SIZES
MAIN & CIRCUIT
LOAD (AMPS)
TOTAL CONNECTED
(AMPS)
TOTAL DEMAND LOAD
(KVA)
DESIGN LOAD
OVERCURRENT
LOAD CENTER "B"100 AMPS 2P (MAIN)19.78 24.73 2.97
B-1 40 AMPS 2P (BRANCH)4.44 5.55
B-2 40 AMPS 2P (BRANCH)15.34 19.18
SPARE 40 AMPS 2P (SPARE)
15
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
L-4
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLDTLT01.dgnUSER: 5lamarj 1/13/2022 4:43:00 PM Default
442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
POLE DATA AND LEGEND
MAX./MIN.
UNIFORMITY RATIO AVG./MIN.4:1 OR LESS
10:1 OR LESS
AVERAGE INITIAL INTENSITY (HORIZONTAL FOOT CANDLES)
AVERAGE INITIAL INTENSITY (VERTICAL FOOT CANDLES)
1.5 FOOT CANDLES
1.2 FOOT CANDLES
DESIGN WIND SPEED 160 MPH
90°
0°180°
270°
ORIENTATION DIAGRAM
PROPOSED PULL BOX
DESCRIPTION
A
LABEL
LUMINAIRE SYMBOLS
LEGEND
B
EXISTING POLE TO BE REMOVED
J PROPOSED JUNCTION BOX
EXISTING PULL BOX
LIGHTING ILLUMINATION CRITERIA
C
D
INSTALL DIRECTIONAL BORE 2" CONDUIT WITH CONDUCTORS
INSTALL BRIDGE MOUNTED 2" CONDUIT WITH CONDUCTORS
INSTALL OPEN TRENCH 2" CONDUIT WITH CONDUCTORS
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.ES2-P35S-40K-MVOLT-TG3.
MPL2 MEMPHIS UTILITY TEARDROP LED
DECORATIVE LUMINAIRE. LIGHTING PHOTOMETRICS BASED ON
OF NEW DIRECT BURIAL, DECORATIVE LIGHT POLE AND
DESIGNED FOR TYPE III DISTRIBUTION. SYMBOL CONSISTS
COLOR TEMPERATURE, WIRED FOR 120 VOLT OPERATION.
144 WATTS (15375 LUMENS) LED LUMINAIRE 40K (4000 CCT)
MEMPHIS UTILITY TEARDROP LED ES2-P35S-40K-MVOLT-TG3.
LUMINAIRE. LIGHTING PHOTOMETRICS BASED ON MPL2
OF NEW BRIDGE MOUNTED LIGHT POLE AND DECORATIVE
DESIGNED FOR TYPE III DISTRIBUTION. SYMBOL CONSISTS
COLOR TEMPERATURE, WIRED FOR 120 VOLT OPERATION.
144 WATTS (15375 LUMENS) LED LUMINAIRE 40K (4000 CCT)
TPX TRIPLEX ALUMINUM CONDUCTOR 600V URD CABLE
* DIRECT BURIAL DECORATIVE CONCRETE POLE TO BE INSTALLED IN ACCORDANCE WITH FDOT STANDARD PLANS INDEX 641-010
ATB2_P40B_MVOLT_R4_3K_RFD323976
POLE WITH 6' MOUNTING ARM. PHOTOMETRICS BASED ON
OF ATB2 FIXTURE MOUNTED ON EXISTING FPL TRANSMISSION
DESIGNED FOR TYPE III DISTRIBUTION. SYMBOL CONSISTS
COLOR TEMPERATURE, WIRED FOR 120 VOLT OPERATION.
133 WATTS (15627 LUMENS) LED LUMINAIRE 3K (3000 CCT)
FPL INSTALLED POLE DATA
NO.
POLE CIRCUIT STATION POLE OFFSET
ON
CONFIGURATI
ARM
LENGTH
ARM ARM LOCATION FOUNDATION WATTAGE
LUMINAIRE
LUMNINAIRES
NUMBER OF
HEIGHT
MOUNTING PAY ITEM
1 CKT-A-1 271+25 62' LT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
2 CKT-A-1 271+12 51' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
3 CKT-A-1 272+51 68' LT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
4 CKT-A-1 272+65 51' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
5 CKT-A-1 274+25 61' LT BRACKET
DECORATIVE 6'POLE
DECORATIVE INSTALL LUMINAIRE ONLY 144 1 30'AND INSTALL
FPL TO FURNISH
6 CKT-B-2 274+25 60' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE INSTALL LUMINAIRE ONLY 144 1 30'AND INSTALL
FPL TO FURNISH
7 CKT-B-1 275+44 66' LT BRACKET ARM 6'
POLE
TRANSMISSION
FPL
N/A 133 1 30'AND INSTALL
FPL TO FURNISH
8 CKT-B-2 275+41 46' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE INSTALL LUMINAIRE ONLY 144 1 30'AND INSTALL
FPL TO FURNISH
9 CKT-B-1 277+33 70' LT BRACKET ARM 6'
POLE
TRANSMISSION
FPL
N/A 133 1 30'AND INSTALL
FPL TO FURNISH
10 CKT-B-2 276+63 58' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
11 CKT-B-1 278+85 70' LT BRACKET ARM 6'
POLE
TRANSMISSION
FPL
N/A 133 1 30'AND INSTALL
FPL TO FURNISH
12 CKT-B-2 278+22 49' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
13 CKT-B-1 280+17 71' LT BRACKET ARM 6'
POLE
TRANSMISSION
FPL
N/A 133 1 30'AND INSTALL
FPL TO FURNISH
14 CKT-B-2 279+71 55' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE DIRECT BURIAL 144 1 30'AND INSTALL
FPL TO FURNISH
FDOT INSTALLED POLE DATA
NO.
POLE CIRCUIT STATION POLE OFFSET ORIENTATION
ARM ANGLE
LENGTH
ARM ARM LOCATION FOUNDATION WATTAGE
LUMINAIRE
LUMNINAIRES
NUMBER OF
HEIGHT
MOUNTING PAY ITEM
5 CKT-A-1 274+25 61' LT BRACKET
DECORATIVE 6'POLE
DECORATIVE
BRACKET ONLY
INSTALL BRIDGE MOUNTED POLE AND FIXTURE 144 1 30'715 535 130
6 CKT-B-2 274+25 60' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE
BRACKET ONLY
INSTALL BRIDGE MOUNTED POLE AND FIXTURE 144 1 30'715 535 130
8 CKT-B-2 275+41 46' RT BRACKET
DECORATIVE 6'POLE
DECORATIVE
POLE AND FIXTURE BRACKET ONLY.*
INSTALL DIRECT BURIAL DECORATIVE CONCRETE 144 1 30'715 4 50
16
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
165 166 167 168 169 170 171 172
268 269 270 271 272
SR 5 (US I)
£ SURVEY
¡ CONST.BLVD.NORTHLAKER/W LINE
R/W LINE
R/W LINE
R/W LINE
W/ #1/0 TPX CONDUCTOR
(UNDER GND)
75 LF
112 LF
1 EA
715-1-60
715-4-70
2" CONDUIT
FPL CONTRACTOR TO F&I
2" CONDUIT
(BORE)
110 LF 2 RUNS 2" CONDUIT
FPL CONTRACTOR TO F&I
W/ #1/0 TPX CONDUCTOR
FPL CONTRACTOR TO F&I
W/ #1/0 TPX CONDUCTOR
EXISTING POLES AND CONDUCTORS
FDOT CONTRACTOR TO REMOVE
STA. 271+11.71 ¡ CONST.
BEGIN PROJECT
(BORE)
88 LF
FPL CONTRACTOR TO F&I
LIGHT POLE 2 CKT-A-1
271+12, 51'RT
FPL CONTRACTOR TO F&I
LIGHT POLE 1 CKT-A-1
271+25. 62'LT
6" WM
(4) 1.5" HDPE Conduits
Fiber Aerial
Crown Castle
6" WM
8" WM
6" FM
8" WM
BE 3-1/0 & 1/12CU Neutral
& 3/0T Neutral
OE- 13KV 3-568TTX Line
138 kV
Gas Main
4" PE
Fiber Optic Cable
2-2" Conduits w/48FSM
Existing PBC-Traffic ITS
6" FM
(4) 1.5" HDPE Conduits
Crown Castle Fiber LLC
Fiber Optic Cable
2-2" Conduits w/48FSM
Existing PBC-Traffic ITS
UNKNOWN UTIL.Lumen Fiber Aerial
Lumen (3) 1.25" HDPE Conduits
WATERWATERBACK FLOWWATERWATERWATERWATERWATERBACK FLOWWATERBACK FLOWWATERWATERELECWATERN50
Feet
0 10
442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING PLAN
L-5MATCH LINE STA. 272+00.00pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT01.DGNUSER: 5lamarj 1/13/2022 4:43:03 PM Default
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.17
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
172 173 174 175 176 177
11
272 273 274 275 276 277 278 279BRIDGE No. 930003
R/W LINE
£ SURVEY
¡ CONST.
SR 5 (US I)
SR 5 (US I)
£ SURVEY
1 EA
1 EA
680 LF
5 EA
635-2-11
715-1-60
715-4-70
¡ CONST.
PULL BOX
(BORE)
159 LF
(BORE)
118 LF
CONDUCTOR
W/ #1/0 TPX
1 EA
1 EA
635-2-11 PULL BOX
W/ #1/0 TPX CONDUCTOR
44 LF (UNDER GND)
2" CONDUIT
FPL CONTRACTOR TO F&I
W/ #1/0 TPX CONDUCTOR
2" CONDUIT
W/ #1/0 TPX CONDUCTOR
FPL CONTRACTOR TO F&I
FDOT CONTRACTOR TO F&I
MOUNTED JUNCTION BOX
630-2-15
715-1-15
46 LF (BRIDGE MOUNTED)
FDOT CONTRACTOR TO F&I
189 LF #1/0 OH CONDUCTOR
FPL CONTRACTOR TO F&I
152 LF #1/0 OH CONDUCTOR
FPL CONTRACTOR TO F&I
2" CONDUIT
FPL CONTRACTOR TO F&I
MOUNTED JUNCTION BOX 635-3-12
FDOT CONTRACTOR TO F&I
630-2-15
715-1-15
38 LF (BRIDGE MOUNTED)
FDOT CONTRACTOR TO F&I
630-2-15 46 LF BRIDGE MOUNTED
715-1-15
2" CONDUIT
W/ #1/0 TPX CONDUCTOR
FPL CONTRACTOR TO F&I
715-535-1301 EA
2" CONDUIT
FPL CONTRACTOR TO F&I
W/ #1/0 TPX CONDUCTOR
FPL CONTRACTOR TO F&I
W/ #1/0 TPX CONDUCTOR
2" CONDUIT 2" CONDUIT
EXISTING POLES AND CONDUCTORS
FDOT CONTRACTOR TO REMOVE
715-535-130 1 EA
FDOT CONTRACTOR TO F&I
635-3-12
635-2-12
ELEC PULL BOX
1 EA
46 LF (#1/0 TPX CONDUCTOR)
715-500-1 1 EA
715-7-11
635-2-11 1 EA
639-3-11 1 EA
641-2-12 1 EA
1 AS
£ SURVEY
715-500-1 1 EA
715-4-50 1 EA
715-500-1 1 EA
(UNDER GRD)
83 LFTO F&I
FPL CONTRACTOR
51 LF (UNDER GND)
(BORE)
125 LF
630-2-15
715-1-15
46 LF (BRIDGE MOUNTED)
FDOT CONTRACTOR TO F&I
(#1/0 TPX CONDUCTOR)
46 LF
SEE LIGHTING DETAIL SHEET (2)
MOUNTED JUNCTION BOX
FDOT CONTRACTOR TO F&I
STA 274+65
SEE LIGHTING DETAIL SHEET (2)
MOUNTED JUNCTION BOX
FDOT CONTRACTOR TO F&I
STA 274+19
30 LF (UNDER GND)
2" CONDUIT (BORE)
73 LF
FPL CONTRACTOR TO F&I
W/ #1/0 TPX CONDUCTOR
LOAD CENTER A
STA. 273+05 RT
SEE LIGHTING DETAIL SHEET (1)
MOUNTED JUNCTION BOX
FDOT CONTRACTOR TO F&I
STA 274+19
TX TLN: 6-8130-6308-0-5
FPL POWER SOURCE
SEE LIGHTING DETAIL SHEET (1)
MOUNTED JUNCTION BOX
FDOT CONTRACTOR TO F&I
STA 274+65
46 LF #1/0 CONDUCTOR
FPL CONTRACTOR TO F&I
LIGHT POLE 4 CKT-A-1
272+65, 51'RT
POLE WITH BRACKET ARM ONLY
FDOT CONTRACTOR TO INSTALL
LIGHT POLE 6 CKT-B-2
274+25, 60'RT
POLE WITH BRACKET ARM ONLY
FDOT CONTRACTOR TO INSTALL
LIGHT POLE 8 CKT-B-2
275+41, 46'RT
FPL CONTRACTOR TO F&I
LIGHT POLE 10 CKT-B-2
276+63, 58'RT
FPL CONTRACTOR TO F&I
LIGHT POLE 12 CKT-B-2
278+22, 49'RT
FPL CONTRACTOR TO F&I
LIGHT POLE 3 CKT-A-1
272+51, 68'LT
POLE WITH BRACKET ARM ONLY
FDOT CONTRACTOR TO INSTALL
LIGHT POLE 5 CKT-A-1
274+25, 61'LT
ARM ON POLE
LUMINAIRE AND BRACKET
FPL CONTRACTOR TO F&I
LIGHT POLE 9 CKT-B-1
277+33, 70'LT
ARM ON POLE
LUMINAIRE AND BRACKET
FPL CONTRACTOR TO F&I
LIGHT POLE 7 CKT-B-1
275+44, 66'LT
ARM ON POLE
LUMINAIRE AND BRACKET
LIGHT POLE 11 CKT-B-1
278+85, 70'LT
38 LF (#1/0 TPX CONDUCTOR)
(4) 1.5" HDPE Conduits
Crown Castle Fiber LLC
Fiber Aerial
Crown Castle
(4) 1.5" HDPE Conduits
Crown Castle Fiber LLC
8" WM
10" WM
8" WM
& 3/0T Neutral
OE- 13KV 3-568T
& 3/0T Neutral
OE- 13KV 3-568T
&1/0T Neutral
OE -13KV 3-3/0T
& 1/12CU
BE 3-1/0
TX Line
138 kV
4" PE Gas Main
Fiber Optic Cable
2-2" Conduits w/48FSM
Existing PBC-Traffic ITS
Fiber Optic Cable
2-2" Conduits w/48FSM
Existing PBC-Traffic ITS
Lumen (3) 1.25" HDPE Conduits
JJ
J J
J
J
J
WATERWATERWATERWATERWATERGASGASWATERWATERBACK FLOWBACK FLOWBACK FLOWWATERWATER15" RCPN50
Feet
0 10
442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING PLAN
MATCH LINE STA. 172+00.00L-6MATCH LINE STA. 279+00.00pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT02.DGNUSER: 5lamarj 1/13/2022 4:43:05 PM Default
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.18
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
12 13 14 15 16
279 280 281 282 283
ANCHORAGE DR.ANCHORAGE DR.SR 5 (US I)
R/W LINE
R/W LINE
R/W LINE
R/W LINE
280 LF
REMOVAL ITEMS
2 EA
715-1-60
715-4-70
132 LF #1/0 OH CONDUCTOR
FPL CONTRACTOR TO F&I
EXISTING POLES AND CONDUCTORS
FDOT CONTRACTOR TO REMOVE
¡ CONST.
STA. 280+39.71
END PROJECT
1 AS
1 EA
1 EA
1 EA 635-2-11
641-2-12
639-3-11
715-7-11
(UNDER GRD)
83 LF
W/ #1/0 TPX CONDUCTOR
2" CONDUIT
FPL CONTRACTOR TO F&I
67 LF (UNDER GRD)
LOAD CENTER B
STA. 280+17 LT
TX TLN: 6-8130-5423-0-2
FPL POWER SOURCE
FPL CONTRACTOR TO F&I
LIGHT POLE 13 CKT-B-1
280+17, 71'LT
FPL CONTACTOR TO F&I
LIGHT POLE 14 CKT-B-2
279+71, 55'RT
2 RUNS- 2" CONDUIT (BORE)
130 LF #1/0 TPX CONDUCTOR
FPL CONTRACTOR TO F&I
Fiber Aerial
Crown Castle
(2) 1.5" HDPE Conduits
Crown Castle Fiber LLC
8" WM
& 3/0T Neutral
OE- 13KV 3-568T
TX Line
138 kV
4" PE Gas Main
Fiber Optic Cable
2-2" Conduits w/48FSM
Existing PBC-Traffic ITS WATERWATERWATERWATERWATERWATERN50
Feet
0 10
L-7 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING PLAN
THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.MATCH LINE STA. 279+00.00pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT03.DGNUSER: 5lamarj 1/13/2022 4:43:07 PM Default
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770
19
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
J J
UNDERWATER LIGHTING BY OTHERS.
CAP CONDUIT FOR FUTURE
WATER LEVEL.
SIGN JUNCTION BOX TO EXISTING
SOUTH SIDE OF BRIDGE PILE FROM
2" BRIDGE CONDUIT MOUNTED ON
UNDERWATER LIGHTING BY OTHERS.
CAP CONDUIT FOR FUTURE
WATER LEVEL.
SIGN JUNCTION BOX TO EXISTING
NORTH SIDE OF BRIDGE PILE FROM
2" BRIDGE CONDUIT MOUNTED ON NEAST SIDE OF BRIDGE
ELEVATION
BRIDGE CONDUIT JUNCTION BOXES
BENT #2 EAST FACE OF BRIDGE
MOUNTED JUNCTION BOX ON
BENT #3
LOGO SIGN JUNCTION BOX
FROM FACE OF BRIDGE TO
USE FLEXIBLE CONDUIT
SIDE OF BENT #2 PILE CAP
JUNCTION BOX ON SOUTH
MOUNT NPB LOGO SIGN
TO LIGHT POLE PILASTER
USE FLEXIBLE CONDUIT FROM JUNCTION BOX
LOGO SIGN JUNCTION BOX
FROM FACE OF BRIDGE TO
USE FLEXIBLE CONDUIT
SIDE OF BENT #3 PILE CAP
JUNCTION BOX ON NORTH
MOUNT NPB LOGO SIGN
CONDUIT
CONDUIT AND/OR FLEXIBLE
INSTALL BRIDGE MOUTNED
LIGHTING DETAIL SHEET (4)
SEE BRIDGE MOUNTED CONDUIT DETAIL
2" BRIDGE MOUNTED CONDUIT
LIGHTING DETAIL SHEET (4)
SEE CONDUIT EXPANSION JOINT DETAIL
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT04.DGN5lamarj1/13/2022 4:43:11 PM Default
L-8 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING DETAIL SHEET (1)
TO BE INSTALLED BY FDOT CONTRACTOR
VILLAGE OF NORTH PALM BEACH LOGO
1 EA700-5-40
1 EA635-3-12
20 LF630-2-15
STA. 274+19 PILASTER FOR BRIDGE MOUNTED LIGHT POLE #5
STA. 274+25
1 EA700-5-40
1 EA635-3-12
20 LF630-2-15
STA. 274+65
SEE LIGHTING DETAIL SHEET (3)
FACE OF BENT #3 PILE CAP
NPB LOGO SIGN MOUNTED ON EAST
SEE LIGHTING DETAIL SHEET (3)
FACE OF BENT #2 PILE CAP
NPB LOGO SIGN MOUNTED ON EAST
20
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
WEST SIDE OF BRIDGE
ELEVATION
J J
UNDERWATER LIGHTING BY OTHERS.
CAP CONDUIT FOR FUTURE
WATER LEVEL.
SIGN JUNCTION BOX TO EXISTING
NORTH SIDE OF BRIDGE PILE FROM
2" BRIDGE CONDUIT MOUNTED ON
UNDERWATER LIGHTING BY OTHERS.
CAP CONDUIT FOR FUTURE
WATER LEVEL.
SIGN JUNCTION BOX TO EXISTING
SOUTH SIDE OF BRIDGE PILE FROM
2" BRIDGE CONDUIT MOUNTED ON NVILLAGE OF NORTH PALM BEACH LOGO
BRIDGE CONDUIT JUNCTION BOXES
BENT #3
EAST FACE OF BRIDGE
MOUNTED JUNCTION BOX ON
BENT #2
LOGO SIGN JUNCTION BOX
FROM FACE OF BRIDGE TO
USE FLEXIBLE CONDUIT
SIDE OF BENT #3 PILE CAP
JUNCTION BOX ON NORTH
MOUNT NPB LOGO SIGN
LOGO SIGN JUNCTION BOX
FROM FACE OF BRIDGE TO
USE FLEXIBLE CONDUIT
SIDE OF BENT #2 PILE CAP
JUNCTION BOX ON SOUTH
MOUNT NPB LOGO SIGN
CONDUIT
CONDUIT AND/OR FLEXIBLE
INSTALL BRIDGE MOUTNED
LIGHTING DETAIL SHEET (4)
SEE CONDUIT EXPANSION JOINT DETAIL
LIGHTING DETAIL SHEET (4)
SEE BRIDGE MOUNTED CONDUIT DETAIL
2" BRIDGE MOUNTED CONDUIT
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT04.DGN5lamarj1/13/2022 4:43:11 PM Default
L-9 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING DETAIL SHEET (2)
TO BE INSTALLED BY FDOT CONTRACTOR
VILLAGE OF NORTH PALM BEACH LOGO
SEE LIGHTING DETAIL SHEET (3)
FACE OF BENT #3 PILE CAP
NPB LOGO SIGN MOUNTED ON WEST
1 EA700-5-40
1 EA635-3-12
20 LF630-2-15
STA. 274+65
PILASTER FOR BRIDGE MOUNTED LIGHT POLE #6
STA. 274+25
TO LIGHT POLE PILASTER
USE FLEXIBLE CONDUIT FROM JUNCTION BOX
SEE LIGHTING DETAIL SHEET (3)
FACE OF BENT #2 PILE CAP
NPB LOGO SIGN MOUNTED ON WEST
1 EA700-5-40
1 EA635-3-12
20 LF630-2-15
STA. 274+19
21
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
4"
4"
RETURNS
.040 ALUMINUM
EDGE
JEWELITE TRIMCAP
DISCONNECT SWITCH
UL 20 AMP, TOGGLE TYPE
MODULES
LED STRIP
LETTER AS REQ'D
BAFFLE (TYP) PER
HOLES W/ LIGHT
1/4" DIA. DRAIN30"30"
LOGO SIGN ATTACHMENT DETAIL
J
2" CONDUIT FOR FUTURE UNDERWATER LIGHTING BY OTHERS
JUNCTION BOX MOUNTED ON SIDE OF PILE CAP
LED POWER SUPPLY INSIDE OF NPB LOGO SIGN
PLEXIGLASS FACE OF NPB LOGO SIGN
MIN. (4) TOTAL
SEE NOTE 1. ANCHORS
TAP CON, 3/16" x 1 3/4'
UL/UV RATED 18GA. CABLE INSIDE CONDUIT
WITH FDOT STRUCTURES MANUAL, VOLUME 1, SECTION 1.6
USE ADHESIVE BONDED ANCHOR SYSTEMS IN ACCORDANCE1.
NOTES:
BENT PILE CAP
2" FLEXIBLE CONDUIT WITH 3- #4 CONDUCTORS
VILLAGE OF NORTH PALM BEACH LOGO
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT04.DGN5lamarj1/13/2022 4:43:12 PM Default
L-10 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING DETAIL SHEET (3)
22
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
FACE OF BRIDGE
2" CONDUIT
8"
1'-6"8"EXPANSION JOINT
FACE OF BRIDGE
2" Ø CONDUIT
EXPANSION FITTING
18"8"2" CONDUIT
2" CONDUIT
FACE OF BRIDGE
JUNCTION BOX
BRIDGE MOUNTED
FRONT VIEW
SIDE VIEW
FACE OF BRIDGE8"8"
2" CONDUIT
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT04.DGN5lamarj1/13/2022 4:43:12 PM Default
L-11 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
LIGHTING DETAIL SHEET (4)
W/ PIPE CLAMP
CHANNEL STRIP APPLICATIONS
MATERIAL FOR STRUCTURAL
USE ADHESIVE BONDING
SPECIFICATIONS
MANUFACTURERS
HOLE DIAMETER PER
BRIDGE MOUNTED ATTACHMENT DETAIL
MOUNTED JUNCTION BOX
SPECIFICATIONS
MANUFACTURERS
HOLE DIAMETER PER
APPLICATIONS
MATERIAL FOR STRUCTURAL
USE ADHESIVE BONDING
MOUNTED JUNCTION BOX
BOLT HOLE LOCATIONS AND SIZES.
CONTRACTOR SHALL COORDINATE WITH JUNCTION BOX SUPPLIERS FOR3.
STRUCTURES MANUAL VOLUME 1 SECTION 1.6.
USE ADHESIVE BONDING ANCHOR SYSTEMS IN ACCORDANCE WITH FDOT2.
ALL MOUNTING HARDWARE SHALL BE STAINLESS STEEL.1.
MOUNTED JUNCTION BOX NOTES:
JOINT DETAIL
BRIDGE MOUNTED CONDUIT EXPANSION
BEAM (FSB)
BOTTOM OF FLORIDA SLAB 7"BRIDGE PEDESTRIAN RAILING
FORMED HOLES PERMITTED
CAST-IN INSERTS OR
NO FIELD DRILLED HOLES,
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.USE SCHEDULE 80 PVC OR FIBERGLASS REINFORCED EPOXY CONDUIT. 3.
STRUCTURES MANUAL VOLUME 1 SECTION 1.6.
USE ADHESIVE BONDING ANCHOR SYSTEMS IN ACCORDANCE WITH FDOT2.
CONDUIT ATTACHMENT SUPPLIERS FOR BOLT HOLE LOCATIONS AND SIZES.
CONTRACTOR SHALL COORDINATE WITH CONDUIT CLAMP AND1.
CONDUIT NOTES:
23
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT04.DGN5lamarj1/13/2022 4:43:12 PM Default
L-12 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
SERVICE POINT DETAIL (1)
4'12'8'36'29'8'7' UNDERGROUND FEED
AERIAL FEED
DETAIL A
DETAIL B1'1'GENERAL NOTES: 5'-6" (MAX.)4' (MIN.)4' (Min.) 5'-6" (Max.) 5'-6" (MAX.) 5'-6" (MAX.)4' (MIN.)4' (MIN.)GROUND ROD (TYP.)6" (MIN.) DEPTH TO(Typ.)30"CLAD (ALL SERVICE POINTS)
" DIA. 40' LONG COPPER 8
5
U.L. APPROVED GROUND ROD,(Typ.)30"GROUND ROD (TYP.)6" (MIN.) DEPTH TOFOR DRAINAGE (TYP.)
OR CRUSHED STONE
12" BED OF PEAROCK
FOR DRAINAGE (TYP.)
OR CRUSHED STONE
12" BED OF PEAROCK
4. A Pull Box is required at each service point, see Index 635-001.
3. Shop drawings are not required for service equipment, unless noted in the plans.
and applicable local codes.
2. The service installation shall meet the requirements of the national electric code
as per the plans and service specifications.
1. It shall be the contractors responsibility to provide a complete service assembly
AS REQUIRED BY POWER COMPANY
CONDUCTOR WEATHERHEAD HEIGHT
STEEL CONDUIT
RIGID GALVANIZED
"2
1CONDUCTOR IN
GROUNDING ELECTRODE
#6 AWG INSULATED
STEEL CONDUIT
RIGID GALVANIZED
" 2
1CONDUCTOR IN
GROUNDING ELECTRODE
#6 AWG INSULATED
CONCRETE POLE PRESTRESSED TYPE P-II, 36' LONG
CONCRETE POLE, PRESTRESSED TYPE P-II, 12' LONG
PULL BOX
CONCRETE PAD
AND GROUND ROD
GROUND, BOND WIRE,
CONNECTION FOR POLE
AND GROUND ROD
GROUND, BOND WIRE,
CONNECTION FOR POLE
CLEVIS WITH INSULATORS
BY POWER COMPANY
HEIGHT SPECIFIED
METER AS REQUIRED
BY POWER COMPANY
HEIGHT SPECIFIED
METER AS REQUIRED
SERVICE DISCONNECTSERVICE DISCONNECT
GRADE
PULL BOX
CONCRETE PAD
GRADE
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.24
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
pw:\\american-pw.bentley.com:american-pw-01\Documents\FDOT\Projects\5174363\TWO-ACE09\44289115201\LIGHTING\PLANLT04.DGN5lamarj1/13/2022 4:43:13 PM Default
L-13 442891-1-52-01 PALM BEACH SR 5
ROAD NO.FINANCIAL PROJECT IDCOUNTY
DATE DESCRIPTION
REVISIONS
DATE DESCRIPTION
NO.
SHEETSTATE OF FLORIDA
DEPARTMENT OF TRANSPORTATION
SERVICE POINT DETAIL (2)
7
1 20220
3 20
2 20
4 20
11
10
19
5
12
15
14
PC 16
8
21
11
10
CKT.1
CKT.3
CKT.2
CKT.4
9 (TYP.)
ONE LINE DIAGRAM DISTRIBUTION POINT
AH
OFF
15
14
5
13
17
16
4TO ITEM19
1
3
5 6
4
2
GROUND BUS
CIRCUIT 1
CIRCUIT 1
CIRCUIT 3
CIRCUIT 3
CIRCUIT 5
CIRCUIT 5
GROUND
CIRCUIT 2
CIRCUIT 2
CIRCUIT 4
CIRCUIT 4
CIRCUIT 6
CIRCUIT 6
GROUND
10
11
9
TYPICAL DISTRIBUTION POINT SCHEMATIC DETAIL
8
522
10
18 18
11
9
19
TO ELECTRICAL SERVICE DROP
RISER DIAGRAM - TYPICAL DISTRIBUTION POINT
2"
PHOTOELECTRIC CONTROLLER DETAIL
KEYED NOTES:
6
12
NEUTRAL BAR
ELECTRIC CONTROLLER.
PLEXIGLASS AND A CLEAR SILICONE SEALANT TO COVER HOLE, INSTALL PHOTO
THE OPERATION AND MOUNTING OF THE PHOTO ELECTRIC CONTROLLER. USE
CUT A 2" HOLE IN THE SIDE OF THE LIGHTING CONTROL PANEL ENCLOSURE FOR
SIDE OR BACK OF ENCLOSURE
PHOTOELECTRIC CONTROLLER
CONSULTING ENGINEERS OF FLORIDA, LLC
AMERICAN
Phone: (561) 253-9550
West Palm Beach, FL 33411
2041 Vista Parkway, Suite 101
Gordon D. Ziecina, P.E., No. 33770 THE OFFICIAL RECORD OF THIS SHEET IS THE ELECTRONIC FILE DIGITALLY SIGNED AND SEALED UNDER RULE 61G15-23.004, F.A.C.HIGH MAST LIGHTING SYSTEMS.
NEMA 4X SST GROUND MOUNTED STORAGE CABINET WITH TWO SHELVES. ONLY REQUIRED FOR 22.
GROUND BUS.21.
MOUNT ON RISER POLE.20.
UNDERGROUND FEEDER CONDUIT.19.
CONCRETE PAD.18.
FOR CLARITY).
HAND-OFF AUTOMATIC SELECTOR SWITCH (PART OF LIGHTING CONTACTOR, SHOWN OUTSIDE17.
120V PHOTOELECTRIC CELL, 1800VA WITH 2000V PEAK SURGE PROTECTION.16.
2 POLE ELECTRICAL LIGHTING CONTACTOR.15.
LIGHTING CONTROL PANEL MAIN BREAKER.14.
LIGHTNING ARRESTER MOUNTED ON OUTSIDE OF ENCLOSURE.13.
CONTACTOR, SHOWN OUTSIDE FOR CLARITY).
FUSED CONTROL POWER TRANSFORMER IF NECESSARY (PART OF LIGHTING 12.
SERVICE MAIN DISCONNECT.
#6 INSULATED COPPER GROUND WIRE. BOND THE SERVICE NEUTRAL TO GROUND AT11.
Ƅ" COPPER CLAD GROUND ROD, 40' LONG.10.
BRANCH CIRCUIT TO ROADWAY LUMINAIRES.9.
INDICATED ON DISTRIBUTION POINT DESCRIPTION ON LIGHTING PLAN SHEETS.
ELECTRICAL PANEL. NUMBER AND RATING OF BRANCH CIRCUIT BREAKERS SHALL BE AS8.
WEATHERHEAD.7.
CONCRETE RISER POLE.6.
FOR EQUIPMENT INSIDE. GROUND MOUNTED CABINET PER INDEX 639-002.
LIGHTING CONTROL PANEL ENCLOSURE (NEMA 4X SST). DIMENSIONS AS NECESSARY5.
SERVICE MAIN DISCONNECT.4.
METER SOCKET BY CONTRACTOR3.
SERVICE FEEDER IN RIGID GALVANIZED STEEL CONDUIT.2.
120/240V, SINGLE PHASE 3 WIRE ELECTRIC DISTRIBUTION OVERHEAD SERVICE DROP.1.
25
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF
SECTION NO.: 93040000 / 02
FM No.(s): 442891-1-52-01
COUNTY: Palm Beach
S.R. No.: SR 5/US 1
EXHIBIT C
MAINTENANCE PLAN REQUIREMENTS
In reference to Maintenance to be performed under this AGREEMENT, the AGENCY shall
submit to the DEPARTMENT a maintenance plan detailing the means and methods for
accomplishing any maintenance or repairs to the IMPROVEMENTS in accordance with all
DEPARTMENT Standards, Procedures and Specifications. This plan shall be submitted and
approved by the DEPARTMENT prior to commencing any maintenance or repair activities. The
AGENCY shall comply with the DEPARTMENT's applicable Maintenance Rating Program
Standards. The plan should at minimum detail how the AGENCY will address the following:
1. Providing for continuous traffic control and necessary traffic control devices as required
for the safe movement of traffic of vehicular and pedestrian traffic past the location of
the structure being repaired for the duration of the repair in accordance with
DEPARTMENT Standards, Procedures and Specifications.
2. Protection of adjacent surrounding property, real estate, vehicles, pedestrians,
attachments to the light poles, or other assets during the preparation and recoating of
surfaces.
3. Containment of debris or materials used in or resulting from the repair.
After the maintenance plan is approved, the AGENCY shall submit a work plan to the
DEPARTMENT for approval prior to each repair to be performed detailing:
1. The proposed date of the repair
2. The location of the repair
3. The nature of the repair
4. The materials to be used for the repair
5. The methods to be used for the repair
26
DocuSign Envelope ID: DC1C4F9B-050C-44F4-A370-C7DBC9F05DEF